SYMPTOM POSSIBLE PROBLEMS SERVICE
Preparing Tool for Operation—Battery/Charger Problems
Normal Stage of Operation
Pre-Combustion/Combustion Stage of Operation
— Fan does not run
—tool LED is off.
— Fan does not run, or
runs slower than normal
—tool LED is red.
— Battery is not charged.
— Battery Terminals or
Magazine battery contacts
are oily, dirty, or corroded.
— Battery is discharged.
— Charge Battery according to Operating Manual.
— Clean Battery terminals. Clean Magazine Battery
terminals as required.
— Charge Battery.
TROUBLESHOOTING
TROUBLESHOOTING
15
— Safety Yoke does not
depress fully—tool
does not operate.
— Tool will not cycle-fan
runs, LED is green.
— Head or Sleeve Steel
Ring damaged.
— Fuel Cell is empty.
— Spark Wire out of spark
plug.
— Spark does not occur.
— Contact Authorized Ramset Distributor Sales
Representative for service.
— Replace Fuel Cell.
— Contact Authorized Ramset Distributor Sales
Representative for service.
— Contact Authorized Ramset Distributor
Sales Representative for service.
— Battery does not appear
to accept charge. Green
charger light does not
come on.
— Flashing lights on
charger base unit.
— Inoperative indicator
lights on charger.
— Battery damaged or
cycle life exhausted.
— Damaged charger.
— Damaged Battery
— Try Battery in tool after 3 hours on charge cycle.
If tool LED is green, charger lights are not working
properly. Replace charger, monitor charging time
to ensure Battery has adequate time for recharging.
It’s normal for Battery to feel warm after properly
charging.
— Replace Battery.
— Discontinue use immediately and unplug from
power source. Replace charger and tag or
dispose of charger to prevent accidental reuse
or connection to power source.
— Replace Battery